RS485 Modbus RTU Class 0.5 Accuracy True RMS 3-Phase 4-Wire
LG6400P Energy Meter
Supply Voltage 80–300V AC
Sampling 128 /cycle
Accuracy
Class 0.5 IEC 62053
Sampling
128 samples/cycle
Panel Size
96 × 96 mm
Interface
RS485 Modbus RTU
Why it is useful

One meter for every electrical parameter your operation needs

LG6400P replaces multiple individual instruments — voltmeter, ammeter, power meter, energy meter, and power quality analyser — in a single 96×96 mm panel unit with Modbus RTU for IoT connectivity.

Comprehensive 3-Phase Monitoring

Measures V, A, kW, kVA, kVAR, kWh, PF, Hz, and THD across all 3 phases simultaneously — from a single panel instrument replacing multiple meters.

RS485 Modbus RTU Integration

Standard Modbus RTU over RS485 connects LG6400P to IoT gateways, PLCs, DCS, and SCADA systems — supporting up to 247 devices on a single bus.

Class 0.5 True RMS Accuracy

128 samples/cycle simultaneous sampling with ±1% Class 0.5 accuracy ensures reliable readings even with non-linear and variable industrial loads and harmonics.

Use Cases

Where LG6400P
fits well

Install LG6400P where a single panel instrument needs to cover all electrical parameters — from billing-grade energy measurement to power quality analysis.

  • DG Set (generator) monitoring — load, energy output, PF, frequency, and runtime via Aether IoT integration.
  • LT panels and MCC panels in industrial facilities — monitoring feeder loads, consumption, and power quality.
  • Distribution boards in commercial buildings — tenant sub-metering and energy billing verification.
  • Renewable energy systems — solar inverter output monitoring and grid import/export measurement (4-quadrant energy).
  • Motor and pump panels — load efficiency monitoring with programmable slots for Watts and Current across 5 time slots.
Features and Specifications

Product Specifications

LG6400P measures and communicates complete 3-phase electrical parameters via Modbus RTU. The details below highlight specifications most relevant for panel installation and IoT integration planning.

Electrical Measurement

PhasesSingle Phase (1P+N) / 3-Phase 3-Wire / 3-Phase 4-Wire
ConfigurationField programmable — Star (Wye), Delta, Single Phase
Rated voltage50 – 600V LL (True RMS)
Rated current10 mA – 6A (via CT, programmable up to 2000 MVA)
Frequency45 – 65 Hz
Sampling rate128 samples/cycle (simultaneous V & A)
Measurement typeTrue RMS, 1-second update, 4-quadrant power & energy
Accuracy classClass 1.0 (IEC 62053-21) standard; Class 0.5S / 0.2S optional
Permissible overload120% voltage; 200% current (momentary)

Parameters Measured

VoltageV, V1, V2, V3, V12, V23, V31 + unbalance
CurrentA, A1, A2, A3 + unbalance
PowerkW, kVA, kVAR (3-phase + individual)
Power FactorPF, PF1, PF2, PF3
Frequency / RPMHz, RPM, Phase angle
Energy (import)kWh, kVAh, kVARh (inductive & capacitive)
Energy (export)kWh export, kVAh export, kVARh export
Harmonics (THD)Voltage & Current THD up to 15th harmonic
DemandkW, kVA, kVAR demand & max demand (sliding)
OtherCO₂ emissions, ON hours, power interruptions count

RS485 / Modbus

ProtocolModbus RTU
InterfaceRS485 (optically isolated)
Device ID1 – 247 (programmable)
ParityOdd, Even, None (Even preferred)
Baud rates2400, 4800, 9600 (preferred), 19200, 38400 bps
Isolation2000V AC for 1 minute (communication vs. other circuits)
Front LED pulse16,000 imp/kWh
IoT integrationVia TRB145 RS485/Modbus gateway to Aether platform

IoT Setup with Aether

Gateway deviceTRB145 RS485/Modbus IoT gateway (Teltonika)
Multi-meter busUp to 247 LG6400P meters on single RS485 loop
PlatformAether Energy Monitoring dashboard
Data availablekWh, kW, kVAR, V, A, PF, Hz per feeder/panel
AlertsDemand threshold, over-voltage, under-voltage alerts
Register mapDynamic register map — programmable address & parameter sequence

Physical & Power

Panel cutout96 × 96 mm
Overall dimensions96 × 96 × 90 mm (W × H × D)
Weight275 g (unpacked), 350 g (packed)
Display3-row LED, 14mm height, 4 digits per row (alpha-numeric)
Auxiliary supply80 – 300V AC/DC (40–300V AC/DC optional)
Power consumption4 VA max
ProtectionIP51 (IP54 front fascia optional), Double Insulation
Wire gauge11 AWG; Terminal torque: 1 N-m

Environmental & Standards

Operating temp-10°C to +55°C
Storage temp-25°C to +70°C
Humidity5% to 95% non-condensing
AltitudeBelow 2000 m
Safety standardIEC/EN 61010-1 Ed.3, CAT III 300V LN / 600V LL, Class II
Energy standardIEC/EN 62052-11, UL 61010-1
EMCIEC 61000-4-2/3/4/5/6/8/11, CISPR-22
CertificationCE (Intertek), Class I & II metering
Aether Integration

Connect energy meter data to the Aether platform

Aether connects LG6400P Modbus data — via a TRB145 RS485 gateway — into energy dashboards with live kWh, load trend reports, demand alerts, and multi-site energy visibility.

Energy Monitoring kWh Tracking DG Set Monitoring Demand Alerts Modbus RTU
  • Live electrical parameters — voltage, current, kW, PF, and frequency — on Aether energy dashboards per feeder or panel.
  • Energy consumption trends — hourly, daily, and monthly kWh tracking for billing reconciliation and efficiency analysis.
  • Demand alerts — notifications when kW or kVA demand exceeds configured thresholds to avoid excess tariff charges.
  • Multi-panel deployment — read from multiple LG6400P meters via a single RS485 bus (up to 247 devices) using the TRB145 gateway.
FAQ

Common questions about LG6400P

LG6400P measures voltage (3-phase + line-to-line), current, kW, kVA, kVAR, kWh (import/export), kVAh, kVARh, power factor, frequency, RPM, phase angle, THD up to 15th harmonic, demand, max demand, CO₂ emissions, and power interruption count — all from a single 96×96 mm panel instrument.
LG6400P communicates via RS485 Modbus RTU. It connects to the Aether energy monitoring platform through a TRB145 RS485/Modbus IoT gateway. Up to 247 meters can be daisy-chained on a single RS485 bus, with each meter addressed uniquely (1–247) for multi-panel monitoring from a single gateway.
The standard LG6400P is Class 1.0 per IEC 62053-21. Class 0.5S (IEC 62053-22) and Class 0.2S options are available for billing-grade applications. The meter uses 128 samples/cycle simultaneous True RMS measurement for accuracy even with non-linear loads and harmonics.
Yes. LG6400P is designed for use with external CTs (current transformers). The CT and PT ratios are field-programmable up to 2000 MVA — making it compatible with virtually any existing MV/LV installation without rewiring the power circuit.
LG6400P fits standard 96×96 mm panel cutouts — suitable for DG set control panels, LT distribution panels, MCC (motor control centres), feeder panels, distribution boards, and solar inverter panels. Its wide auxiliary supply range (80–300V AC/DC) allows installation across different voltage systems without a separate power supply.

Need help choosing the right tracker?

Share your panel type, number of meters, and energy monitoring goals. Aether can design the LG6400P + TRB145 gateway solution for your site and connect it to the energy monitoring platform.

Talk to Aether